About Tap Position Indicator - TDC 6001
Product Details:
| Display | standardized |
| Current Output | standardized |
| Accuracy | standardized |
| Usage/Application | standardized |
| Color | standardized |
| Brand | standardized |
| Power Rating | standardized |
We are a preeminent organization engaged in manufacturing, supplying and exporting Total Performance Indicator. To ensure the high standards of offered performance indicators, we make use of quality approved raw material and latest technology in their manufacturing process. In addition to this, we strictly follow globally accepted quality norms while manufacturing these performance indicators.
Mentioned below are the attributes of the offered performance indicators:
- Durability
- Robust construction
- Reliable performance
- Easy maintenance
Robust and Reliable Analog DisplayThe TDC 6001 Tap Position Indicator features a large, clearly marked analog dial that allows precise reading of transformer tap positions, supporting up to 35 positions. The meter is robustly constructed with a powder-coated, corrosion-resistant body to withstand harsh industrial conditions.
Flexible Input and Mounting OptionsDesigned for versatility, this indicator accepts either Potential Free Contact or 12V/24V DC signals for input, facilitating integration with a variety of control systems. The panel mounting design along with secure screw terminals ensures easy installation and a reliable connection.
Safety, Compliance, and Easy MaintenanceBuilt to meet IS/IEC standards, the TDC 6001 features an IP55-rated enclosure for dust and weather protection. Its insulation box offers enhanced electrical safety, and calibration can be adjusted directly in the field, ensuring continued accuracy and low maintenance requirements.
FAQs of Tap Position Indicator - TDC 6001:
Q: How do I install the TDC 6001 Tap Position Indicator on my transformer panel?
A: The TDC 6001 is designed for straightforward panel mounting using its standardized dimensions (144x144x100 mm) and secure screw terminals. Ensure the panel cutout matches the indicators specifications, and follow the wiring guide to connect input signals and power, maintaining correct polarity and enclosure sealing.
Q: What kind of signals can the analog display interpret, and how is this useful?
A: The TDC 6001 accepts Potential Free Contact or 12V/24V DC signals, making it compatible with a wide range of OLTC systems and control panels. This flexibility allows for easy integration into both existing and new transformer setups, enhancing user convenience.
Q: When should I recalibrate the device, and how is calibration performed?
A: Recalibration is recommended whenever the transformer tap changer is serviced or if any drift in the indicator reading is observed. Field calibration is simple: adjust the calibration settings as per the dial markings to match the actual tap position, ensuring 1 tap accuracy.
Q: Where can I use the TDC 6001, considering environmental factors?
A: This indicator is ideal for use in power substations, transformer rooms, and outdoor locations exposed to dust and humidity, thanks to its weatherproof (IP55) enclosure, corrosion-resistant MS body, and operation range of -10C to +55C at up to 95% RH (non-condensing).
Q: What benefits does the analog meter offer compared to digital alternatives?
A: The clear analog dial provides rapid visual updates, requires minimal power (less than 3 VA), and performs reliably even in electrically noisy environments. Its rugged design ensures consistent operation and a long service life in industrial settings.
Q: How does the insulation box contribute to the devices safety?
A: The included insulation box enhances electrical insulation, safeguarding both the device and personnel from accidental electrical contact, especially useful when handling high voltage equipment in substations and transformer enclosures.
Q: What warranty and after-sales support are provided for the TDC 6001?
A: The TDC 6001 comes with a manufacturers warranty. For detailed coverage and support, customers can directly contact the supplier or manufacturer in India to address any performance, installation, or service queries.